part_subject: "CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES"
subpart_code: "D"
subpart_subject: "Emission Test Equipment Provisions"
section_number: "89.315"
section_subject: "Analyzer bench checks."
cfr_reference: "40 CFR 89.315"
title_name: "Title 40"
title_subject: "Protection of Environment"
parts_covered: "Parts 87 to 95"
revised_date: "Revised as of July 1, 2017"
publication_date: "As of July 1, 2017"
contains_description: "Containing a codification of documents of general applicability and future effect"
publication_info: "Published by the Office of the Federal Register National Archives and Records Administration as a Special Edition of the Federal Register"
---
(a)Prior to initial use and after major repairs verify that each analyzer complies with the specifications given in Table 3 in appendix A of this subpart.
(b)If a stainless steel NO2 to NO converter is used, condition all new or replacement converters. The conditioning consists of either purging the converter with air for a minimum of 4 hours or until the converter efficiency is greater than 90 percent. The converter must be at operational temperature while purging. Do not use this procedure prior to checking converter efficiency on in-use converters.