part_subject: "STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES"
subpart_code: "E"
subpart_subject: "a—Standards of Performance for Municipal Waste Combustors for Which Construction Is Commenced After December 20, 1989 and On or Before September 20, 1994"
section_number: "60.53a"
section_subject: "Standard for municipal waste combustor organics."
cfr_reference: "40 CFR 60.53a"
title_name: "Title 40"
title_subject: "Protection of Environment"
parts_covered: "Part 60 (§§ 60.1 to 60.499)"
revised_date: "Revised as of July 1, 2019"
publication_date: "As of July 1, 2019"
contains_description: "Containing a codification of documents of general applicability and future effect"
publication_info: "Published by the Office of the Federal Register National Archives and Records Administration as a Special Edition of the Federal Register"
(b)On and after the date on which the initial compliance test is completed or is required to be completed under § 60.8, no owner or operator of an affected facility located within a large MWC plant shall cause to be discharged into the atmosphere from that affected facility any gases that contain dioxin/furan emissions that exceed 30 nanograms per dry standard cubic meter (12 grains per billion dry standard cubic feet), corrected to 7 percent oxygen (dry basis).