(a)Within 180 days after your final compliance date in table 1 of this subpart, you must meet the two limitations specified in paragraphs (a)(1) and (2) of this section.
(1)The opacity limitation is 10 percent (6-minute average), except as described in paragraph (a)(2) of this section.
(2)The opacity limitation is 35 percent (6-minute average) during the startup period that is within the first 30 minutes of operation.
(b)The limitations in paragraph (a) of this section apply at all times except during malfunctions.